1Alarm Code in v1.1+ Alarm Message in v1.0- Alarm Description
21Hard limitHard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
32Soft limitSoft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked.
43Abort during cycleReset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
54Probe failProbe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered.
65Probe failProbe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4.
76Homing failHoming fail. The active homing cycle was reset.
87Homing failHoming fail. Safety door was opened during homing cycle.
98Homing failHoming fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring.
109Homing failHoming fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring.