(KEY: Alarm Code in v1.1+, Alarm Message in v1.0-, Alarm Description)
|
||||
1,Hard limit,Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
|
||||
2,Soft limit,Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked.
|
||||
3,Abort during cycle,Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
|
||||
4,Probe fail,Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered.
|
||||
5,Probe fail,Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4.
|
||||
6,Homing fail,Homing fail. The active homing cycle was reset.
|
||||
7,Homing fail,Homing fail. Safety door was opened during homing cycle.
|
||||
8,Homing fail,Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring.
|
||||
9,Homing fail,Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring.
|
||||
"Alarm Code in v1.1+"," Alarm Message in v1.0-"," Alarm Description"
|
||||
"1","Hard limit","Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
|
||||
"2","Soft limit","Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked."
|
||||
"3","Abort during cycle","Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
|
||||
"4","Probe fail","Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered."
|
||||
"5","Probe fail","Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4."
|
||||
"6","Homing fail","Homing fail. The active homing cycle was reset."
|
||||
"7","Homing fail","Homing fail. Safety door was opened during homing cycle."
|
||||
"8","Homing fail","Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring."
|
||||
"9","Homing fail","Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring."
|
||||
|
|
@ -1,35 +1,35 @@
|
||||
(KEY: Error Code in v1.1+ ,Error Message in v1.0-, Error Description)
|
||||
1,Expected command letter,G-code words consist of a letter and a value. Letter was not found.
|
||||
2,Bad number format,Missing the expected G-code word value or numeric value format is not valid.
|
||||
3,Invalid statement,Grbl '$' system command was not recognized or supported.
|
||||
4,Value < 0,Negative value received for an expected positive value.
|
||||
5,Setting disabled,Homing cycle failure. Homing is not enabled via settings.
|
||||
6,Value < 3 usec,Minimum step pulse time must be greater than 3usec.
|
||||
7,EEPROM read fail. Using defaults,An EEPROM read failed. Auto-restoring affected EEPROM to default values.
|
||||
8,Not idle,Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job.
|
||||
9,G-code lock,G-code commands are locked out during alarm or jog state.
|
||||
10,Homing not enabled,Soft limits cannot be enabled without homing also enabled.
|
||||
11,Line overflow,Max characters per line exceeded. Received command line was not executed.
|
||||
12,Step rate > 30kHz,Grbl '$' setting value cause the step rate to exceed the maximum supported.
|
||||
13,Check Door,Safety door detected as opened and door state initiated.
|
||||
14,Line length exceeded,Build info or startup line exceeded EEPROM line length limit. Line not stored.
|
||||
15,Travel exceeded,Jog target exceeds machine travel. Jog command has been ignored.
|
||||
16,Invalid jog command,Jog command has no '=' or contains prohibited g-code.
|
||||
20,Unsupported command,Unsupported or invalid g-code command found in block.
|
||||
21,Modal group violation,More than one g-code command from same modal group found in block.
|
||||
22,Undefined feed rate,Feed rate has not yet been set or is undefined.
|
||||
23,Invalid gcode ID:23,G-code command in block requires an integer value.
|
||||
24,Invalid gcode ID:24,More than one g-code command that requires axis words found in block.
|
||||
25,Invalid gcode ID:25,Repeated g-code word found in block.
|
||||
26,Invalid gcode ID:26,No axis words found in block for g-code command or current modal state which requires them.
|
||||
27,Invalid gcode ID:27,Line number value is invalid.
|
||||
28,Invalid gcode ID:28,G-code command is missing a required value word.
|
||||
29,Invalid gcode ID:29,G59.x work coordinate systems are not supported.
|
||||
30,Invalid gcode ID:30,G53 only allowed with G0 and G1 motion modes.
|
||||
31,Invalid gcode ID:31,Axis words found in block when no command or current modal state uses them.
|
||||
32,Invalid gcode ID:32,G2 and G3 arcs require at least one in-plane axis word.
|
||||
33,Invalid gcode ID:33,Motion command target is invalid.
|
||||
34,Invalid gcode ID:34,Arc radius value is invalid.
|
||||
35,Invalid gcode ID:35,G2 and G3 arcs require at least one in-plane offset word.
|
||||
36,Invalid gcode ID:36,Unused value words found in block.
|
||||
37,Invalid gcode ID:37,G43.1 dynamic tool length offset is not assigned to configured tool length axis.
|
||||
"Error Code in v1.1+ ","Error Message in v1.0-"," Error Description"
|
||||
"1","Expected command letter","G-code words consist of a letter and a value. Letter was not found."
|
||||
"2","Bad number format","Missing the expected G-code word value or numeric value format is not valid."
|
||||
"3","Invalid statement","Grbl '$' system command was not recognized or supported."
|
||||
"4","Value < 0","Negative value received for an expected positive value."
|
||||
"5","Setting disabled","Homing cycle failure. Homing is not enabled via settings."
|
||||
"6","Value < 3 usec","Minimum step pulse time must be greater than 3usec."
|
||||
"7","EEPROM read fail. Using defaults","An EEPROM read failed. Auto-restoring affected EEPROM to default values."
|
||||
"8","Not idle","Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job."
|
||||
"9","G-code lock","G-code commands are locked out during alarm or jog state."
|
||||
"10","Homing not enabled","Soft limits cannot be enabled without homing also enabled."
|
||||
"11","Line overflow","Max characters per line exceeded. Received command line was not executed."
|
||||
"12","Step rate > 30kHz","Grbl '$' setting value cause the step rate to exceed the maximum supported."
|
||||
"13","Check Door","Safety door detected as opened and door state initiated."
|
||||
"14","Line length exceeded","Build info or startup line exceeded EEPROM line length limit. Line not stored."
|
||||
"15","Travel exceeded","Jog target exceeds machine travel. Jog command has been ignored."
|
||||
"16","Invalid jog command","Jog command has no '=' or contains prohibited g-code."
|
||||
"20","Unsupported command","Unsupported or invalid g-code command found in block."
|
||||
"21","Modal group violation","More than one g-code command from same modal group found in block."
|
||||
"22","Undefined feed rate","Feed rate has not yet been set or is undefined."
|
||||
"23","Invalid gcode ID:23","G-code command in block requires an integer value."
|
||||
"24","Invalid gcode ID:24","More than one g-code command that requires axis words found in block."
|
||||
"25","Invalid gcode ID:25","Repeated g-code word found in block."
|
||||
"26","Invalid gcode ID:26","No axis words found in block for g-code command or current modal state which requires them."
|
||||
"27","Invalid gcode ID:27","Line number value is invalid."
|
||||
"28","Invalid gcode ID:28","G-code command is missing a required value word."
|
||||
"29","Invalid gcode ID:29","G59.x work coordinate systems are not supported."
|
||||
"30","Invalid gcode ID:30","G53 only allowed with G0 and G1 motion modes."
|
||||
"31","Invalid gcode ID:31","Axis words found in block when no command or current modal state uses them."
|
||||
"32","Invalid gcode ID:32","G2 and G3 arcs require at least one in-plane axis word."
|
||||
"33","Invalid gcode ID:33","Motion command target is invalid."
|
||||
"34","Invalid gcode ID:34","Arc radius value is invalid."
|
||||
"35","Invalid gcode ID:35","G2 and G3 arcs require at least one in-plane offset word."
|
||||
"36","Invalid gcode ID:36","Unused value words found in block."
|
||||
"37","Invalid gcode ID:37","G43.1 dynamic tool length offset is not assigned to configured tool length axis."
|
||||
|
|
@ -1,35 +1,35 @@
|
||||
(KEY: $-Code, Setting, Units, Setting Description)
|
||||
0,Step pulse time,microseconds,Sets time length per step. Minimum 3usec.
|
||||
1,Step idle delay,milliseconds,Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay.
|
||||
2,Step pulse invert,mask,Inverts the step signal. Set axis bit to invert (00000ZYX).
|
||||
3,Step direction invert,mask,Inverts the direction signal. Set axis bit to invert (00000ZYX).
|
||||
4,Invert step enable pin,boolean,Inverts the stepper driver enable pin signal.
|
||||
5,Invert limit pins,boolean,Inverts the all of the limit input pins.
|
||||
6,Invert probe pin,boolean,Inverts the probe input pin signal.
|
||||
10,Status report options,mask,Alters data included in status reports.
|
||||
11,Junction deviation,millimeters,Sets how fast Grbl travels through consecutive motions. Lower value slows it down.
|
||||
12,Arc tolerance,millimeters,Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance.
|
||||
13,Report in inches,boolean,Enables inch units when returning any position and rate value that is not a settings value.
|
||||
20,Soft limits enable,boolean,Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing.
|
||||
21,Hard limits enable,boolean,Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered.
|
||||
22,Homing cycle enable,boolean,Enables homing cycle. Requires limit switches on all axes.
|
||||
23,Homing direction invert,mask,Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction.
|
||||
24,Homing locate feed rate,mm/min,Feed rate to slowly engage limit switch to determine its location accurately.
|
||||
25,Homing search seek rate,mm/min,Seek rate to quickly find the limit switch before the slower locating phase.
|
||||
26,Homing switch debounce delay,milliseconds,Sets a short delay between phases of homing cycle to let a switch debounce.
|
||||
27,Homing switch pull-off distance,millimeters,Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared.
|
||||
30,Maximum spindle speed,RPM,Maximum spindle speed. Sets PWM to 100% duty cycle.
|
||||
31,Minimum spindle speed,RPM,Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle.
|
||||
32,Laser-mode enable,boolean,Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed.
|
||||
100,X-axis travel resolution,step/mm,X-axis travel resolution in steps per millimeter.
|
||||
101,Y-axis travel resolution,step/mm,Y-axis travel resolution in steps per millimeter.
|
||||
102,Z-axis travel resolution,step/mm,Z-axis travel resolution in steps per millimeter.
|
||||
110,X-axis maximum rate,mm/min,X-axis maximum rate. Used as G0 rapid rate.
|
||||
111,Y-axis maximum rate,mm/min,Y-axis maximum rate. Used as G0 rapid rate.
|
||||
112,Z-axis maximum rate,mm/min,Z-axis maximum rate. Used as G0 rapid rate.
|
||||
120,X-axis acceleration,mm/sec^2,X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
|
||||
121,Y-axis acceleration,mm/sec^2,Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
|
||||
122,Z-axis acceleration,mm/sec^2,Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
|
||||
130,X-axis maximum travel,millimeters,Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
|
||||
131,Y-axis maximum travel,millimeters,Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
|
||||
132,Z-axis maximum travel,millimeters,Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
|
||||
"$-Code"," Setting"," Units"," Setting Description"
|
||||
"0","Step pulse time","microseconds","Sets time length per step. Minimum 3usec."
|
||||
"1","Step idle delay","milliseconds","Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay."
|
||||
"2","Step pulse invert","mask","Inverts the step signal. Set axis bit to invert (00000ZYX)."
|
||||
"3","Step direction invert","mask","Inverts the direction signal. Set axis bit to invert (00000ZYX)."
|
||||
"4","Invert step enable pin","boolean","Inverts the stepper driver enable pin signal."
|
||||
"5","Invert limit pins","boolean","Inverts the all of the limit input pins."
|
||||
"6","Invert probe pin","boolean","Inverts the probe input pin signal."
|
||||
"10","Status report options","mask","Alters data included in status reports."
|
||||
"11","Junction deviation","millimeters","Sets how fast Grbl travels through consecutive motions. Lower value slows it down."
|
||||
"12","Arc tolerance","millimeters","Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance."
|
||||
"13","Report in inches","boolean","Enables inch units when returning any position and rate value that is not a settings value."
|
||||
"20","Soft limits enable","boolean","Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing."
|
||||
"21","Hard limits enable","boolean","Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered."
|
||||
"22","Homing cycle enable","boolean","Enables homing cycle. Requires limit switches on all axes."
|
||||
"23","Homing direction invert","mask","Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction."
|
||||
"24","Homing locate feed rate","mm/min","Feed rate to slowly engage limit switch to determine its location accurately."
|
||||
"25","Homing search seek rate","mm/min","Seek rate to quickly find the limit switch before the slower locating phase."
|
||||
"26","Homing switch debounce delay","milliseconds","Sets a short delay between phases of homing cycle to let a switch debounce."
|
||||
"27","Homing switch pull-off distance","millimeters","Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared."
|
||||
"30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle."
|
||||
"31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle."
|
||||
"32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed."
|
||||
"100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter."
|
||||
"101","Y-axis travel resolution","step/mm","Y-axis travel resolution in steps per millimeter."
|
||||
"102","Z-axis travel resolution","step/mm","Z-axis travel resolution in steps per millimeter."
|
||||
"110","X-axis maximum rate","mm/min","X-axis maximum rate. Used as G0 rapid rate."
|
||||
"111","Y-axis maximum rate","mm/min","Y-axis maximum rate. Used as G0 rapid rate."
|
||||
"112","Z-axis maximum rate","mm/min","Z-axis maximum rate. Used as G0 rapid rate."
|
||||
"120","X-axis acceleration","mm/sec^2","X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
|
||||
"121","Y-axis acceleration","mm/sec^2","Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
|
||||
"122","Z-axis acceleration","mm/sec^2","Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
|
||||
"130","X-axis maximum travel","millimeters","Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
|
||||
"131","Y-axis maximum travel","millimeters","Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
|
||||
"132","Z-axis maximum travel","millimeters","Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
|
||||
|
|