- Wrap value in quotes to avoid issue with embedded commas. This occurs in one of the alarm codes. - Change header row format to allow same parsing code as data rows.
1.2 KiB
1.2 KiB
1 | Alarm Code in v1.1+ | Alarm Message in v1.0- | Alarm Description |
---|---|---|---|
2 | 1 | Hard limit | Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. |
3 | 2 | Soft limit | Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked. |
4 | 3 | Abort during cycle | Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. |
5 | 4 | Probe fail | Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered. |
6 | 5 | Probe fail | Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4. |
7 | 6 | Homing fail | Homing fail. The active homing cycle was reset. |
8 | 7 | Homing fail | Homing fail. Safety door was opened during homing cycle. |
9 | 8 | Homing fail | Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring. |
10 | 9 | Homing fail | Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring. |