Modify code CSV format. (#10)

- Wrap value in quotes to avoid issue with embedded commas. This occurs
  in one of the alarm codes.

- Change header row format to allow same parsing code as data rows.
This commit is contained in:
Will Winder 2016-10-17 06:50:15 -07:00 committed by Sonny Jeon
parent 62d16af285
commit c8ac98d6e0
3 changed files with 80 additions and 80 deletions

View File

@ -1,10 +1,10 @@
(KEY: Alarm Code in v1.1+, Alarm Message in v1.0-, Alarm Description)
1,Hard limit,Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
2,Soft limit,Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked.
3,Abort during cycle,Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
4,Probe fail,Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered.
5,Probe fail,Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4.
6,Homing fail,Homing fail. The active homing cycle was reset.
7,Homing fail,Homing fail. Safety door was opened during homing cycle.
8,Homing fail,Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring.
9,Homing fail,Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring.
"Alarm Code in v1.1+"," Alarm Message in v1.0-"," Alarm Description"
"1","Hard limit","Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
"2","Soft limit","Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked."
"3","Abort during cycle","Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
"4","Probe fail","Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered."
"5","Probe fail","Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4."
"6","Homing fail","Homing fail. The active homing cycle was reset."
"7","Homing fail","Homing fail. Safety door was opened during homing cycle."
"8","Homing fail","Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring."
"9","Homing fail","Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring."

1 (KEY: Alarm Code in v1.1+, Alarm Message in v1.0-, Alarm Description) Alarm Code in v1.1+ Alarm Message in v1.0- Alarm Description
2 1,Hard limit,Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. 1 Hard limit Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
3 2,Soft limit,Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked. 2 Soft limit Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked.
4 3,Abort during cycle,Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. 3 Abort during cycle Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
5 4,Probe fail,Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered. 4 Probe fail Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered.
6 5,Probe fail,Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4. 5 Probe fail Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4.
7 6,Homing fail,Homing fail. The active homing cycle was reset. 6 Homing fail Homing fail. The active homing cycle was reset.
8 7,Homing fail,Homing fail. Safety door was opened during homing cycle. 7 Homing fail Homing fail. Safety door was opened during homing cycle.
9 8,Homing fail,Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring. 8 Homing fail Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring.
10 9,Homing fail,Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring. 9 Homing fail Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring.

View File

@ -1,35 +1,35 @@
(KEY: Error Code in v1.1+ ,Error Message in v1.0-, Error Description)
1,Expected command letter,G-code words consist of a letter and a value. Letter was not found.
2,Bad number format,Missing the expected G-code word value or numeric value format is not valid.
3,Invalid statement,Grbl '$' system command was not recognized or supported.
4,Value < 0,Negative value received for an expected positive value.
5,Setting disabled,Homing cycle failure. Homing is not enabled via settings.
6,Value < 3 usec,Minimum step pulse time must be greater than 3usec.
7,EEPROM read fail. Using defaults,An EEPROM read failed. Auto-restoring affected EEPROM to default values.
8,Not idle,Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job.
9,G-code lock,G-code commands are locked out during alarm or jog state.
10,Homing not enabled,Soft limits cannot be enabled without homing also enabled.
11,Line overflow,Max characters per line exceeded. Received command line was not executed.
12,Step rate > 30kHz,Grbl '$' setting value cause the step rate to exceed the maximum supported.
13,Check Door,Safety door detected as opened and door state initiated.
14,Line length exceeded,Build info or startup line exceeded EEPROM line length limit. Line not stored.
15,Travel exceeded,Jog target exceeds machine travel. Jog command has been ignored.
16,Invalid jog command,Jog command has no '=' or contains prohibited g-code.
20,Unsupported command,Unsupported or invalid g-code command found in block.
21,Modal group violation,More than one g-code command from same modal group found in block.
22,Undefined feed rate,Feed rate has not yet been set or is undefined.
23,Invalid gcode ID:23,G-code command in block requires an integer value.
24,Invalid gcode ID:24,More than one g-code command that requires axis words found in block.
25,Invalid gcode ID:25,Repeated g-code word found in block.
26,Invalid gcode ID:26,No axis words found in block for g-code command or current modal state which requires them.
27,Invalid gcode ID:27,Line number value is invalid.
28,Invalid gcode ID:28,G-code command is missing a required value word.
29,Invalid gcode ID:29,G59.x work coordinate systems are not supported.
30,Invalid gcode ID:30,G53 only allowed with G0 and G1 motion modes.
31,Invalid gcode ID:31,Axis words found in block when no command or current modal state uses them.
32,Invalid gcode ID:32,G2 and G3 arcs require at least one in-plane axis word.
33,Invalid gcode ID:33,Motion command target is invalid.
34,Invalid gcode ID:34,Arc radius value is invalid.
35,Invalid gcode ID:35,G2 and G3 arcs require at least one in-plane offset word.
36,Invalid gcode ID:36,Unused value words found in block.
37,Invalid gcode ID:37,G43.1 dynamic tool length offset is not assigned to configured tool length axis.
"Error Code in v1.1+ ","Error Message in v1.0-"," Error Description"
"1","Expected command letter","G-code words consist of a letter and a value. Letter was not found."
"2","Bad number format","Missing the expected G-code word value or numeric value format is not valid."
"3","Invalid statement","Grbl '$' system command was not recognized or supported."
"4","Value < 0","Negative value received for an expected positive value."
"5","Setting disabled","Homing cycle failure. Homing is not enabled via settings."
"6","Value < 3 usec","Minimum step pulse time must be greater than 3usec."
"7","EEPROM read fail. Using defaults","An EEPROM read failed. Auto-restoring affected EEPROM to default values."
"8","Not idle","Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job."
"9","G-code lock","G-code commands are locked out during alarm or jog state."
"10","Homing not enabled","Soft limits cannot be enabled without homing also enabled."
"11","Line overflow","Max characters per line exceeded. Received command line was not executed."
"12","Step rate > 30kHz","Grbl '$' setting value cause the step rate to exceed the maximum supported."
"13","Check Door","Safety door detected as opened and door state initiated."
"14","Line length exceeded","Build info or startup line exceeded EEPROM line length limit. Line not stored."
"15","Travel exceeded","Jog target exceeds machine travel. Jog command has been ignored."
"16","Invalid jog command","Jog command has no '=' or contains prohibited g-code."
"20","Unsupported command","Unsupported or invalid g-code command found in block."
"21","Modal group violation","More than one g-code command from same modal group found in block."
"22","Undefined feed rate","Feed rate has not yet been set or is undefined."
"23","Invalid gcode ID:23","G-code command in block requires an integer value."
"24","Invalid gcode ID:24","More than one g-code command that requires axis words found in block."
"25","Invalid gcode ID:25","Repeated g-code word found in block."
"26","Invalid gcode ID:26","No axis words found in block for g-code command or current modal state which requires them."
"27","Invalid gcode ID:27","Line number value is invalid."
"28","Invalid gcode ID:28","G-code command is missing a required value word."
"29","Invalid gcode ID:29","G59.x work coordinate systems are not supported."
"30","Invalid gcode ID:30","G53 only allowed with G0 and G1 motion modes."
"31","Invalid gcode ID:31","Axis words found in block when no command or current modal state uses them."
"32","Invalid gcode ID:32","G2 and G3 arcs require at least one in-plane axis word."
"33","Invalid gcode ID:33","Motion command target is invalid."
"34","Invalid gcode ID:34","Arc radius value is invalid."
"35","Invalid gcode ID:35","G2 and G3 arcs require at least one in-plane offset word."
"36","Invalid gcode ID:36","Unused value words found in block."
"37","Invalid gcode ID:37","G43.1 dynamic tool length offset is not assigned to configured tool length axis."

1 (KEY: Error Code in v1.1+ Error Code in v1.1+ Error Message in v1.0- Error Description) Error Description
2 1 Expected command letter G-code words consist of a letter and a value. Letter was not found.
3 2 Bad number format Missing the expected G-code word value or numeric value format is not valid.
4 3 Invalid statement Grbl '$' system command was not recognized or supported.
5 4 Value < 0 Negative value received for an expected positive value.
6 5 Setting disabled Homing cycle failure. Homing is not enabled via settings.
7 6 Value < 3 usec Minimum step pulse time must be greater than 3usec.
8 7 EEPROM read fail. Using defaults An EEPROM read failed. Auto-restoring affected EEPROM to default values.
9 8 Not idle Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job.
10 9 G-code lock G-code commands are locked out during alarm or jog state.
11 10 Homing not enabled Soft limits cannot be enabled without homing also enabled.
12 11 Line overflow Max characters per line exceeded. Received command line was not executed.
13 12 Step rate > 30kHz Grbl '$' setting value cause the step rate to exceed the maximum supported.
14 13 Check Door Safety door detected as opened and door state initiated.
15 14 Line length exceeded Build info or startup line exceeded EEPROM line length limit. Line not stored.
16 15 Travel exceeded Jog target exceeds machine travel. Jog command has been ignored.
17 16 Invalid jog command Jog command has no '=' or contains prohibited g-code.
18 20 Unsupported command Unsupported or invalid g-code command found in block.
19 21 Modal group violation More than one g-code command from same modal group found in block.
20 22 Undefined feed rate Feed rate has not yet been set or is undefined.
21 23 Invalid gcode ID:23 G-code command in block requires an integer value.
22 24 Invalid gcode ID:24 More than one g-code command that requires axis words found in block.
23 25 Invalid gcode ID:25 Repeated g-code word found in block.
24 26 Invalid gcode ID:26 No axis words found in block for g-code command or current modal state which requires them.
25 27 Invalid gcode ID:27 Line number value is invalid.
26 28 Invalid gcode ID:28 G-code command is missing a required value word.
27 29 Invalid gcode ID:29 G59.x work coordinate systems are not supported.
28 30 Invalid gcode ID:30 G53 only allowed with G0 and G1 motion modes.
29 31 Invalid gcode ID:31 Axis words found in block when no command or current modal state uses them.
30 32 Invalid gcode ID:32 G2 and G3 arcs require at least one in-plane axis word.
31 33 Invalid gcode ID:33 Motion command target is invalid.
32 34 Invalid gcode ID:34 Arc radius value is invalid.
33 35 Invalid gcode ID:35 G2 and G3 arcs require at least one in-plane offset word.
34 36 Invalid gcode ID:36 Unused value words found in block.
35 37 Invalid gcode ID:37 G43.1 dynamic tool length offset is not assigned to configured tool length axis.

View File

@ -1,35 +1,35 @@
(KEY: $-Code, Setting, Units, Setting Description)
0,Step pulse time,microseconds,Sets time length per step. Minimum 3usec.
1,Step idle delay,milliseconds,Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay.
2,Step pulse invert,mask,Inverts the step signal. Set axis bit to invert (00000ZYX).
3,Step direction invert,mask,Inverts the direction signal. Set axis bit to invert (00000ZYX).
4,Invert step enable pin,boolean,Inverts the stepper driver enable pin signal.
5,Invert limit pins,boolean,Inverts the all of the limit input pins.
6,Invert probe pin,boolean,Inverts the probe input pin signal.
10,Status report options,mask,Alters data included in status reports.
11,Junction deviation,millimeters,Sets how fast Grbl travels through consecutive motions. Lower value slows it down.
12,Arc tolerance,millimeters,Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance.
13,Report in inches,boolean,Enables inch units when returning any position and rate value that is not a settings value.
20,Soft limits enable,boolean,Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing.
21,Hard limits enable,boolean,Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered.
22,Homing cycle enable,boolean,Enables homing cycle. Requires limit switches on all axes.
23,Homing direction invert,mask,Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction.
24,Homing locate feed rate,mm/min,Feed rate to slowly engage limit switch to determine its location accurately.
25,Homing search seek rate,mm/min,Seek rate to quickly find the limit switch before the slower locating phase.
26,Homing switch debounce delay,milliseconds,Sets a short delay between phases of homing cycle to let a switch debounce.
27,Homing switch pull-off distance,millimeters,Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared.
30,Maximum spindle speed,RPM,Maximum spindle speed. Sets PWM to 100% duty cycle.
31,Minimum spindle speed,RPM,Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle.
32,Laser-mode enable,boolean,Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed.
100,X-axis travel resolution,step/mm,X-axis travel resolution in steps per millimeter.
101,Y-axis travel resolution,step/mm,Y-axis travel resolution in steps per millimeter.
102,Z-axis travel resolution,step/mm,Z-axis travel resolution in steps per millimeter.
110,X-axis maximum rate,mm/min,X-axis maximum rate. Used as G0 rapid rate.
111,Y-axis maximum rate,mm/min,Y-axis maximum rate. Used as G0 rapid rate.
112,Z-axis maximum rate,mm/min,Z-axis maximum rate. Used as G0 rapid rate.
120,X-axis acceleration,mm/sec^2,X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
121,Y-axis acceleration,mm/sec^2,Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
122,Z-axis acceleration,mm/sec^2,Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
130,X-axis maximum travel,millimeters,Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
131,Y-axis maximum travel,millimeters,Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
132,Z-axis maximum travel,millimeters,Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
"$-Code"," Setting"," Units"," Setting Description"
"0","Step pulse time","microseconds","Sets time length per step. Minimum 3usec."
"1","Step idle delay","milliseconds","Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay."
"2","Step pulse invert","mask","Inverts the step signal. Set axis bit to invert (00000ZYX)."
"3","Step direction invert","mask","Inverts the direction signal. Set axis bit to invert (00000ZYX)."
"4","Invert step enable pin","boolean","Inverts the stepper driver enable pin signal."
"5","Invert limit pins","boolean","Inverts the all of the limit input pins."
"6","Invert probe pin","boolean","Inverts the probe input pin signal."
"10","Status report options","mask","Alters data included in status reports."
"11","Junction deviation","millimeters","Sets how fast Grbl travels through consecutive motions. Lower value slows it down."
"12","Arc tolerance","millimeters","Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance."
"13","Report in inches","boolean","Enables inch units when returning any position and rate value that is not a settings value."
"20","Soft limits enable","boolean","Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing."
"21","Hard limits enable","boolean","Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered."
"22","Homing cycle enable","boolean","Enables homing cycle. Requires limit switches on all axes."
"23","Homing direction invert","mask","Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction."
"24","Homing locate feed rate","mm/min","Feed rate to slowly engage limit switch to determine its location accurately."
"25","Homing search seek rate","mm/min","Seek rate to quickly find the limit switch before the slower locating phase."
"26","Homing switch debounce delay","milliseconds","Sets a short delay between phases of homing cycle to let a switch debounce."
"27","Homing switch pull-off distance","millimeters","Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared."
"30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle."
"31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle."
"32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed."
"100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter."
"101","Y-axis travel resolution","step/mm","Y-axis travel resolution in steps per millimeter."
"102","Z-axis travel resolution","step/mm","Z-axis travel resolution in steps per millimeter."
"110","X-axis maximum rate","mm/min","X-axis maximum rate. Used as G0 rapid rate."
"111","Y-axis maximum rate","mm/min","Y-axis maximum rate. Used as G0 rapid rate."
"112","Z-axis maximum rate","mm/min","Z-axis maximum rate. Used as G0 rapid rate."
"120","X-axis acceleration","mm/sec^2","X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
"121","Y-axis acceleration","mm/sec^2","Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
"122","Z-axis acceleration","mm/sec^2","Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
"130","X-axis maximum travel","millimeters","Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
"131","Y-axis maximum travel","millimeters","Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
"132","Z-axis maximum travel","millimeters","Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."

1 (KEY: $-Code $-Code Setting Setting Units Units Setting Description) Setting Description
2 0 Step pulse time microseconds Sets time length per step. Minimum 3usec.
3 1 Step idle delay milliseconds Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay.
4 2 Step pulse invert mask Inverts the step signal. Set axis bit to invert (00000ZYX).
5 3 Step direction invert mask Inverts the direction signal. Set axis bit to invert (00000ZYX).
6 4 Invert step enable pin boolean Inverts the stepper driver enable pin signal.
7 5 Invert limit pins boolean Inverts the all of the limit input pins.
8 6 Invert probe pin boolean Inverts the probe input pin signal.
9 10 Status report options mask Alters data included in status reports.
10 11 Junction deviation millimeters Sets how fast Grbl travels through consecutive motions. Lower value slows it down.
11 12 Arc tolerance millimeters Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance.
12 13 Report in inches boolean Enables inch units when returning any position and rate value that is not a settings value.
13 20 Soft limits enable boolean Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing.
14 21 Hard limits enable boolean Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered.
15 22 Homing cycle enable boolean Enables homing cycle. Requires limit switches on all axes.
16 23 Homing direction invert mask Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction.
17 24 Homing locate feed rate mm/min Feed rate to slowly engage limit switch to determine its location accurately.
18 25 Homing search seek rate mm/min Seek rate to quickly find the limit switch before the slower locating phase.
19 26 Homing switch debounce delay milliseconds Sets a short delay between phases of homing cycle to let a switch debounce.
20 27 Homing switch pull-off distance millimeters Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared.
21 30 Maximum spindle speed RPM Maximum spindle speed. Sets PWM to 100% duty cycle.
22 31 Minimum spindle speed RPM Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle.
23 32 Laser-mode enable boolean Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed.
24 100 X-axis travel resolution step/mm X-axis travel resolution in steps per millimeter.
25 101 Y-axis travel resolution step/mm Y-axis travel resolution in steps per millimeter.
26 102 Z-axis travel resolution step/mm Z-axis travel resolution in steps per millimeter.
27 110 X-axis maximum rate mm/min X-axis maximum rate. Used as G0 rapid rate.
28 111 Y-axis maximum rate mm/min Y-axis maximum rate. Used as G0 rapid rate.
29 112 Z-axis maximum rate mm/min Z-axis maximum rate. Used as G0 rapid rate.
30 120 X-axis acceleration mm/sec^2 X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
31 121 Y-axis acceleration mm/sec^2 Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
32 122 Z-axis acceleration mm/sec^2 Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps.
33 130 X-axis maximum travel millimeters Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
34 131 Y-axis maximum travel millimeters Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.
35 132 Z-axis maximum travel millimeters Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances.