3df61e0ec5
WARNING: Bugs may still exist. This branch is a work in progress and will be pushed to the edge branch when at beta stability. Use at your own risk. - Homing freezing issue fixed. Had to do with the cycle stop flag being set incorrectly after the homing cycles and before the pull-off maneuver. Now resets the stepper motors before this can happen. - Fixed an issue with a rare feed hold failure. Had to do with feed hold ending exactly at the end of a block. The runtime protocol now sets the QUEUED and IDLE states appropriately when this occurs. Still need to clean this code up however, as it’s patched rather than written well. - Updated version build via $I command. - Forgot to comment on a new feature for the last commit. Since steps are integers and millimeters traveled are floats, the old step segment generator ignored the step fraction differences in generating the segment velocities. Didn’t see like it would be much of a big deal, but there were instances that this would be a problem, especially for very slow feed rates. The stepper algorithm now micro-adjusts the segment velocities based on the step fractions not executed from the previous segment. This ensures that Grbl generates the velocity profiles EXACTLY and noticeably improves overall acceleration performance.
285 lines
12 KiB
C
285 lines
12 KiB
C
/*
|
|
protocol.c - controls Grbl execution protocol and procedures
|
|
Part of Grbl
|
|
|
|
Copyright (c) 2011-2014 Sungeun K. Jeon
|
|
Copyright (c) 2009-2011 Simen Svale Skogsrud
|
|
|
|
Grbl is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
Grbl is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with Grbl. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include "system.h"
|
|
#include "serial.h"
|
|
#include "settings.h"
|
|
#include "protocol.h"
|
|
#include "gcode.h"
|
|
#include "planner.h"
|
|
#include "stepper.h"
|
|
#include "motion_control.h"
|
|
#include "report.h"
|
|
|
|
|
|
static char line[LINE_BUFFER_SIZE]; // Line to be executed. Zero-terminated.
|
|
|
|
|
|
// Directs and executes one line of formatted input from protocol_process. While mostly
|
|
// incoming streaming g-code blocks, this also directs and executes Grbl internal commands,
|
|
// such as settings, initiating the homing cycle, and toggling switch states.
|
|
// TODO: Eventually re-organize this function to more cleanly organize order of operations,
|
|
// which will hopefully reduce some of the current spaghetti logic and dynamic memory usage.
|
|
static void protocol_execute_line(char *line)
|
|
{
|
|
protocol_execute_runtime(); // Runtime command check point.
|
|
if (sys.abort) { return; } // Bail to calling function upon system abort
|
|
|
|
uint8_t status;
|
|
if (line[0] == 0) {
|
|
// Empty or comment line. Send status message for syncing purposes.
|
|
status = STATUS_OK;
|
|
|
|
} else if (line[0] == '$') {
|
|
// Grbl '$' system command
|
|
status = system_execute_line(line);
|
|
|
|
} else {
|
|
// Everything else is gcode. Send to g-code parser! Block if in alarm mode.
|
|
if (sys.state == STATE_ALARM) { status = STATUS_ALARM_LOCK; }
|
|
else { status = gc_execute_line(line); }
|
|
|
|
// TODO: Separate the parsing from the g-code execution. Need to re-write the parser
|
|
// completely to do this. First parse the line completely, checking for modal group
|
|
// errors and storing all of the g-code words. Then, send the stored g-code words to
|
|
// a separate g-code executor. This will be more in-line with actual g-code protocol.
|
|
|
|
// TODO: Clean up the multi-tasking workflow with the execution of commands. It's a
|
|
// bit complicated and patch-worked. Could be made simplier to understand.
|
|
}
|
|
|
|
report_status_message(status);
|
|
}
|
|
|
|
|
|
/*
|
|
GRBL MAIN LOOP:
|
|
*/
|
|
void protocol_main_loop()
|
|
{
|
|
// ------------------------------------------------------------
|
|
// Complete initialization procedures upon a power-up or reset.
|
|
// ------------------------------------------------------------
|
|
|
|
// Print welcome message
|
|
report_init_message();
|
|
|
|
// Check for and report alarm state after a reset, error, or an initial power up.
|
|
if (sys.state == STATE_ALARM) {
|
|
report_feedback_message(MESSAGE_ALARM_LOCK);
|
|
} else {
|
|
// All systems go!
|
|
sys.state = STATE_IDLE; // Set system to ready. Clear all state flags.
|
|
system_execute_startup(line); // Execute startup script.
|
|
}
|
|
|
|
// ------------------------------------------------------------------------------
|
|
// Main loop! Upon a system abort, this exits back to main() to reset the system.
|
|
// ------------------------------------------------------------------------------
|
|
|
|
uint8_t iscomment = false;
|
|
uint8_t char_counter = 0;
|
|
uint8_t c;
|
|
for (;;) {
|
|
|
|
// Process one line of incoming serial data, as the data becomes available. Performs an
|
|
// initial filtering by removing spaces and comments and capitalizing all letters.
|
|
while((c = serial_read()) != SERIAL_NO_DATA) {
|
|
if ((c == '\n') || (c == '\r')) { // End of line reached
|
|
line[char_counter] = 0; // Set string termination character.
|
|
protocol_execute_line(line); // Line is complete. Execute it!
|
|
iscomment = false;
|
|
char_counter = 0;
|
|
} else {
|
|
if (iscomment) {
|
|
// Throw away all comment characters
|
|
if (c == ')') {
|
|
// End of comment. Resume line.
|
|
iscomment = false;
|
|
}
|
|
} else {
|
|
if (c <= ' ') {
|
|
// Throw away whitepace and control characters
|
|
} else if (c == '/') {
|
|
// Block delete not supported. Ignore character.
|
|
} else if (c == '(') {
|
|
// Enable comments flag and ignore all characters until ')' or EOL.
|
|
iscomment = true;
|
|
} else if (char_counter >= LINE_BUFFER_SIZE-1) {
|
|
// Detect line buffer overflow. Report error and reset line buffer.
|
|
report_status_message(STATUS_OVERFLOW);
|
|
iscomment = false;
|
|
char_counter = 0;
|
|
} else if (c >= 'a' && c <= 'z') { // Upcase lowercase
|
|
line[char_counter++] = c-'a'+'A';
|
|
} else {
|
|
line[char_counter++] = c;
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
// If there are no more characters in the serial read buffer to be processed and executed,
|
|
// this indicates that g-code streaming has either filled the planner buffer or has
|
|
// completed. In either case, auto-cycle start, if enabled, any queued moves.
|
|
protocol_auto_cycle_start();
|
|
|
|
protocol_execute_runtime(); // Runtime command check point.
|
|
if (sys.abort) { return; } // Bail to main() program loop to reset system.
|
|
|
|
}
|
|
|
|
return; /* Never reached */
|
|
}
|
|
|
|
|
|
// Executes run-time commands, when required. This is called from various check points in the main
|
|
// program, primarily where there may be a while loop waiting for a buffer to clear space or any
|
|
// point where the execution time from the last check point may be more than a fraction of a second.
|
|
// This is a way to execute runtime commands asynchronously (aka multitasking) with grbl's g-code
|
|
// parsing and planning functions. This function also serves as an interface for the interrupts to
|
|
// set the system runtime flags, where only the main program handles them, removing the need to
|
|
// define more computationally-expensive volatile variables. This also provides a controlled way to
|
|
// execute certain tasks without having two or more instances of the same task, such as the planner
|
|
// recalculating the buffer upon a feedhold or override.
|
|
// NOTE: The sys.execute variable flags are set by any process, step or serial interrupts, pinouts,
|
|
// limit switches, or the main program.
|
|
void protocol_execute_runtime()
|
|
{
|
|
uint8_t rt_exec = sys.execute; // Copy to avoid calling volatile multiple times
|
|
if (rt_exec) { // Enter only if any bit flag is true
|
|
|
|
// System alarm. Everything has shutdown by something that has gone severely wrong. Report
|
|
// the source of the error to the user. If critical, Grbl disables by entering an infinite
|
|
// loop until system reset/abort.
|
|
if (rt_exec & (EXEC_ALARM | EXEC_CRIT_EVENT)) {
|
|
sys.state = STATE_ALARM; // Set system alarm state
|
|
|
|
// Critical event. Only hard/soft limit errors currently qualify.
|
|
if (rt_exec & EXEC_CRIT_EVENT) {
|
|
report_alarm_message(ALARM_LIMIT_ERROR);
|
|
report_feedback_message(MESSAGE_CRITICAL_EVENT);
|
|
bit_false(sys.execute,EXEC_RESET); // Disable any existing reset
|
|
do {
|
|
// Nothing. Block EVERYTHING until user issues reset or power cycles. Hard limits
|
|
// typically occur while unattended or not paying attention. Gives the user time
|
|
// to do what is needed before resetting, like killing the incoming stream. The
|
|
// same could be said about soft limits. While the position is not lost, the incoming
|
|
// stream could be still engaged and cause a serious crash if it continues afterwards.
|
|
} while (bit_isfalse(sys.execute,EXEC_RESET));
|
|
|
|
// Standard alarm event. Only abort during motion qualifies.
|
|
} else {
|
|
// Runtime abort command issued during a cycle, feed hold, or homing cycle. Message the
|
|
// user that position may have been lost and set alarm state to enable the alarm lockout
|
|
// to indicate the possible severity of the problem.
|
|
report_alarm_message(ALARM_ABORT_CYCLE);
|
|
}
|
|
bit_false(sys.execute,(EXEC_ALARM | EXEC_CRIT_EVENT));
|
|
}
|
|
|
|
// Execute system abort.
|
|
if (rt_exec & EXEC_RESET) {
|
|
sys.abort = true; // Only place this is set true.
|
|
return; // Nothing else to do but exit.
|
|
}
|
|
|
|
// Execute and serial print status
|
|
if (rt_exec & EXEC_STATUS_REPORT) {
|
|
report_realtime_status();
|
|
bit_false(sys.execute,EXEC_STATUS_REPORT);
|
|
}
|
|
|
|
// Execute a feed hold with deceleration, only during cycle.
|
|
if (rt_exec & EXEC_FEED_HOLD) {
|
|
// !!! During a cycle, the segment buffer has just been reloaded and full. So the math involved
|
|
// with the feed hold should be fine for most, if not all, operational scenarios.
|
|
if (sys.state == STATE_CYCLE) {
|
|
sys.state = STATE_HOLD;
|
|
st_update_plan_block_parameters();
|
|
st_prep_buffer();
|
|
sys.auto_start = false; // Disable planner auto start upon feed hold.
|
|
}
|
|
bit_false(sys.execute,EXEC_FEED_HOLD);
|
|
}
|
|
|
|
// Execute a cycle start by starting the stepper interrupt begin executing the blocks in queue.
|
|
if (rt_exec & EXEC_CYCLE_START) {
|
|
if (sys.state == STATE_QUEUED) {
|
|
sys.state = STATE_CYCLE;
|
|
st_prep_buffer(); // Initialize step segment buffer before beginning cycle.
|
|
st_wake_up();
|
|
if (bit_istrue(settings.flags,BITFLAG_AUTO_START)) {
|
|
sys.auto_start = true; // Re-enable auto start after feed hold.
|
|
} else {
|
|
sys.auto_start = false; // Reset auto start per settings.
|
|
}
|
|
}
|
|
bit_false(sys.execute,EXEC_CYCLE_START);
|
|
}
|
|
|
|
// Reinitializes the cycle plan and stepper system after a feed hold for a resume. Called by
|
|
// runtime command execution in the main program, ensuring that the planner re-plans safely.
|
|
// NOTE: Bresenham algorithm variables are still maintained through both the planner and stepper
|
|
// cycle reinitializations. The stepper path should continue exactly as if nothing has happened.
|
|
// NOTE: EXEC_CYCLE_STOP is set by the stepper subsystem when a cycle or feed hold completes.
|
|
if (rt_exec & EXEC_CYCLE_STOP) {
|
|
if ( plan_get_current_block() ) { sys.state = STATE_QUEUED; }
|
|
else { sys.state = STATE_IDLE; }
|
|
bit_false(sys.execute,EXEC_CYCLE_STOP);
|
|
}
|
|
|
|
}
|
|
|
|
// Overrides flag byte (sys.override) and execution should be installed here, since they
|
|
// are runtime and require a direct and controlled interface to the main stepper program.
|
|
|
|
// Reload step segment buffer
|
|
if (sys.state & (STATE_CYCLE | STATE_HOLD | STATE_HOMING)) { st_prep_buffer(); }
|
|
|
|
}
|
|
|
|
|
|
// Block until all buffered steps are executed or in a cycle state. Works with feed hold
|
|
// during a synchronize call, if it should happen. Also, waits for clean cycle end.
|
|
void protocol_buffer_synchronize()
|
|
{
|
|
// Check and set auto start to resume cycle after synchronize and caller completes.
|
|
if (sys.state == STATE_CYCLE) { sys.auto_start = true; }
|
|
while (plan_get_current_block() || (sys.state == STATE_CYCLE)) {
|
|
protocol_execute_runtime(); // Check and execute run-time commands
|
|
if (sys.abort) { return; } // Check for system abort
|
|
}
|
|
}
|
|
|
|
|
|
// Auto-cycle start has two purposes: 1. Resumes a plan_synchronize() call from a function that
|
|
// requires the planner buffer to empty (spindle enable, dwell, etc.) 2. As a user setting that
|
|
// automatically begins the cycle when a user enters a valid motion command manually. This is
|
|
// intended as a beginners feature to help new users to understand g-code. It can be disabled
|
|
// as a beginner tool, but (1.) still operates. If disabled, the operation of cycle start is
|
|
// manually issuing a cycle start command whenever the user is ready and there is a valid motion
|
|
// command in the planner queue.
|
|
// NOTE: This function is called from the main loop and mc_line() only and executes when one of
|
|
// two conditions exist respectively: There are no more blocks sent (i.e. streaming is finished,
|
|
// single commands), or the planner buffer is full and ready to go.
|
|
void protocol_auto_cycle_start() { if (sys.auto_start) { sys.execute |= EXEC_CYCLE_START; } }
|